Question Paper
Fourth Year B. Arch. EXAMINATION, 2018
ARCHITECTURAL DESIGN
Paper IV
(2008 BRIDGE PATTERN)
Time 18 Hours Maximum Marks 100
N.B. Your design solution will be evaluated as a whole.
(ii Assume suitable data if necessary.
(iii The candidates shall submit single line plans of the entire
scheme with layout plan to the required scale al the end
of first day. These drawings shall not be returned to the
candidates, therefore due record of the same should be
kept for subsequent days. The candidates shall not make
any considerable departure for the design submitted on the
first day.
The drawings should be self-explanatory with structural scheme
and should have clarity in all the plans and sections.
College of Architecture in Rurban Pune
In the newly developing rurban areas of Pune Municipal Corporation,
a private trust is interested in starting a new college of Architecture.
The site has access from 15 m wide road and is located on the
banks of a river.
P.T.O.
[5357]-403 2
The proposed Architecture College has to be designed with the following
requirements
Space requirements (figures indicate carpet area in sq.m)
Note Adequate areas for passages, lobbies, staircases, lifts etc, services
and toilets should be adequately provided wherever required.
Administration
Entrance lobby and reception area 30 sq.m
Principal's cabin and toilet 30 sq.m
Office area for 6 no. administration staff 60 sq.m
Staff room with attached toilet 100 sq.m
Professors cabins 4 nos 15 sq. m each 60 sq.m
Store 15 sq.m
Adequate toilets for both sex
Academic Area
Design studios 5 nos. 120 sq.m each 600 sq.m
Classrooms 4 nos. for 40 students -60 sq.m each 240 sq.m
Class rooms may or may not be combined with
design studios
Material museum and material testing lab 120 sq.m
Climatology lab 30 sq.m
Surveying and leveling lab 30 sq.m
[5357]-403 3 P.T.O.
Computer lab with scanning and potting facility 60 sq.m
Carpentary workhop 120 sq.m
Library 200 sq.m
Other areas
Auditorium 240 sq.m
Canteen with kitchen, washing, store, indoor and
outdoor seating area 150 sq.m
Girls common room 30 sq.m
NASA room 60 sq.m
Sports room (indoor) 60 sq.m
Store 15 sq.m
Reprography facility 15 sq.m
Service area
Electrical transformer, electric meter and panel room 75 sq.m
Generator room 50 sq.m
UG water tank of capacity of 50,000 ltr
Fire fighting system
Parking and security
Cars 10 nos
Tow wheelers 50 nos
Bus 1 no.
Security cabin 1 no.
[5357]-403 4
Design Parameters
1. Minimum setback 9.00 m from Main road and 6 m from other
sides
2. Maximum ground coverage 50%
3. Design should be functionally and structurally stable
4. Provision of barrier free environment for differently abled
5. Structural components should be shown in plan and section
6. Vehicular movement, ramps, headroom etc as per standards.
Drawing requirements
First day
Site zoning
Single line layout plan showing iste development, building
configuration, circulation etc. 1:200
Single line floor plans at all levels 1:200
Final day
Site plan with site development—ground floor plan, access,
roads, parking, landscaped areas and service areas 1:200
All double line floor plan showing furniture layout 1:100
Roof Plan
Building sections minimum 2 1:100
Elevations minimum 2 1:100
ARCHITECTURAL DESIGN
Paper IV
(2008 BRIDGE PATTERN)
Time 18 Hours Maximum Marks 100
N.B. Your design solution will be evaluated as a whole.
(ii Assume suitable data if necessary.
(iii The candidates shall submit single line plans of the entire
scheme with layout plan to the required scale al the end
of first day. These drawings shall not be returned to the
candidates, therefore due record of the same should be
kept for subsequent days. The candidates shall not make
any considerable departure for the design submitted on the
first day.
The drawings should be self-explanatory with structural scheme
and should have clarity in all the plans and sections.
College of Architecture in Rurban Pune
In the newly developing rurban areas of Pune Municipal Corporation,
a private trust is interested in starting a new college of Architecture.
The site has access from 15 m wide road and is located on the
banks of a river.
P.T.O.
[5357]-403 2
The proposed Architecture College has to be designed with the following
requirements
Space requirements (figures indicate carpet area in sq.m)
Note Adequate areas for passages, lobbies, staircases, lifts etc, services
and toilets should be adequately provided wherever required.
Administration
Entrance lobby and reception area 30 sq.m
Principal's cabin and toilet 30 sq.m
Office area for 6 no. administration staff 60 sq.m
Staff room with attached toilet 100 sq.m
Professors cabins 4 nos 15 sq. m each 60 sq.m
Store 15 sq.m
Adequate toilets for both sex
Academic Area
Design studios 5 nos. 120 sq.m each 600 sq.m
Classrooms 4 nos. for 40 students -60 sq.m each 240 sq.m
Class rooms may or may not be combined with
design studios
Material museum and material testing lab 120 sq.m
Climatology lab 30 sq.m
Surveying and leveling lab 30 sq.m
[5357]-403 3 P.T.O.
Computer lab with scanning and potting facility 60 sq.m
Carpentary workhop 120 sq.m
Library 200 sq.m
Other areas
Auditorium 240 sq.m
Canteen with kitchen, washing, store, indoor and
outdoor seating area 150 sq.m
Girls common room 30 sq.m
NASA room 60 sq.m
Sports room (indoor) 60 sq.m
Store 15 sq.m
Reprography facility 15 sq.m
Service area
Electrical transformer, electric meter and panel room 75 sq.m
Generator room 50 sq.m
UG water tank of capacity of 50,000 ltr
Fire fighting system
Parking and security
Cars 10 nos
Tow wheelers 50 nos
Bus 1 no.
Security cabin 1 no.
[5357]-403 4
Design Parameters
1. Minimum setback 9.00 m from Main road and 6 m from other
sides
2. Maximum ground coverage 50%
3. Design should be functionally and structurally stable
4. Provision of barrier free environment for differently abled
5. Structural components should be shown in plan and section
6. Vehicular movement, ramps, headroom etc as per standards.
Drawing requirements
First day
Site zoning
Single line layout plan showing iste development, building
configuration, circulation etc. 1:200
Single line floor plans at all levels 1:200
Final day
Site plan with site development—ground floor plan, access,
roads, parking, landscaped areas and service areas 1:200
All double line floor plan showing furniture layout 1:100
Roof Plan
Building sections minimum 2 1:100
Elevations minimum 2 1:100
Other Question Papers
Subjects
- architectural design
- architectural design—iii
- building services—i
- building services—ii
- building technology and materials
- professional practice
- quantity surveying and estimating
- specification writing
- theory of structures
- theory of structures—iii
- town planning