FEBRUARY 2018 Sub. Code: 2123
B.Sc. NUCLEAR MEDICINE TECHNOLOGY
THIRD YEAR
PAPER III QUALITY ASSURANCE IN NUCLEAR MEDICINE
Q.P. Code: 802123
Time: Three Hours Maximum: 100 Marks
Answer all questions
I. Elaborate on: x 10 30)
1. Describe the general Quality Assurance Test procedures in Scintillation
and Gamma Detectors.
2. Enumerate the Acceptance Tests during installation of Gamma Camera.
3. Draw a model of Nuclear Medicine Diagnostic Department plan and explain
in respect of its public safety, contamination and in Quality Control.
II. Write notes on: x 5 40)
1. COR calibration in H and L mode in SPECT scan.
2. Modulation transfer function.
3. Write about the Jaszcazk phantom in respect of QA procedures.
4. NEMA protocol.
5. Factors affecting SUV.
6. Describe the test for Photo Peak in SPECT scan.
7. Sinogram.
8. Zero adjustment Test.
III. Short answers on: (10 x 3 30)
1. Isotope calibrator.
2. Survey meter.
3. GM Counters.
4. Photo peak.
5. Pin source.
6. Zero adjustment Test.
7. Dead time.
8. Thyroid uptake.
9. Center of rotation.
10. Resolution.
B.Sc. NUCLEAR MEDICINE TECHNOLOGY
THIRD YEAR
PAPER III QUALITY ASSURANCE IN NUCLEAR MEDICINE
Q.P. Code: 802123
Time: Three Hours Maximum: 100 Marks
Answer all questions
I. Elaborate on: x 10 30)
1. Describe the general Quality Assurance Test procedures in Scintillation
and Gamma Detectors.
2. Enumerate the Acceptance Tests during installation of Gamma Camera.
3. Draw a model of Nuclear Medicine Diagnostic Department plan and explain
in respect of its public safety, contamination and in Quality Control.
II. Write notes on: x 5 40)
1. COR calibration in H and L mode in SPECT scan.
2. Modulation transfer function.
3. Write about the Jaszcazk phantom in respect of QA procedures.
4. NEMA protocol.
5. Factors affecting SUV.
6. Describe the test for Photo Peak in SPECT scan.
7. Sinogram.
8. Zero adjustment Test.
III. Short answers on: (10 x 3 30)
1. Isotope calibrator.
2. Survey meter.
3. GM Counters.
4. Photo peak.
5. Pin source.
6. Zero adjustment Test.
7. Dead time.
8. Thyroid uptake.
9. Center of rotation.
10. Resolution.
Other Question Papers
Subjects
- basic physics and nuclear physics
- nuclear medicine techniques and special procedures
- nuclear medicine techniques and
- physics of nuclear medicine instrumentation
- quality assurance in nuclearmedicine
- radiation biology and radiation safety in nuclear medicine
- radiochemistry and radio pharmacy
- radiochemistry and radiopharmacy
- recent advance in nuclear medicine techniques
- recent advance in nuclear medicine
- special procedures
- techniques